Product Details for Material from Asco Numatics - E262C002E7A8 - Asco Numatics Solenoid Valve E262C002E7A8, 2 port , NC, 230 V ac, 1/8in

E262C002E7A8 Asco Numatics Asco Numatics Solenoid Valve E262C002E7A8, 2 port , NC, 230 V ac, 1/8in

Part Nnumber
E262C002E7A8
Description
Asco Numatics Solenoid Valve E262C002E7A8, 2 port , NC, 230 V ac, 1/8in
Producer
Asco Numatics
Basic price
70,51 EUR

The product with part number E262C002E7A8 (Asco Numatics Solenoid Valve E262C002E7A8, 2 port , NC, 230 V ac, 1/8in) is from company Asco Numatics and distributed with basic unit price 70,51 EUR. Minimal order quantity is 1 pc.


Body MaterialBrass Connection1/8 in Rp Female Connection GenderFemale Connection Size1/8in Default Valve PositionNC Flow Factor Kv0.41m³/h Maximum Closing Time1s Maximum Opening Time1s Maximum Operating Temperature+60°C Maximum Working Pressure2.76bar Minimum Operating Temperature0°C Number of Ports2 Operating Temperature Range0 → +60 °C OperationDirect Orifice Diameter3.2mm Series262 Suitable ApplicationsCombustible Gas Supply Voltage230 V ac Thread Standard or Connection TypeRp Type2/2 Product Details Two-way, N/C, Gas Pilot/Burner Control Valves Two-way, direct operated, EN161 approved solenoid valves for use on gas pilot and gas burner control, zero bar minimum operating pressure, normally closed, threaded port connection. Pressure not required for operationCompact & lightweightISO 4400 DIN connectionClass A, group 2 service & Gas families 1 & 2Can be mounted in any position Approvals EN161 Two Way Inert Gases and Fluid Valves Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.


Following Parts

Random Products

(keyword E262C002E7A8 Asco Numatics Asco Numatics Solenoid Valve E262C002E7A8, 2 port , NC, 230 V ac, 1/8in)
© 2015 Industry Server